Programmable Controller Module Robust Offline Sequence Controller for Industrial Automatic Control DC1224V

46,95 €
+ 10,49 € Envío

Programmable Controller Module Robust Offline Sequence Controller for Industrial Automatic Control DC1224V

  • Marca: Unbranded
Vendido por:

Programmable Controller Module Robust Offline Sequence Controller for Industrial Automatic Control DC1224V

  • Marca: Unbranded

46,95 €

Ahorre 12,05 € (20%)

PVP

59,00 €
En existencias
+ 10,49 € Envío
Vendido por:

46,95 €

Ahorre 12,05 € (20%)

PVP

59,00 €
En existencias
+ 10,49 € Envío

Aceptamos los siguientes métodos de pago

Descripción

Feature:1. PROGRAMMABLE FUNCTION: This offline sequence controller has programmable function, which can be customized to set up a great sequence trace according to actual requirements.2. BASIC VALUES: This programmable offline sequence controller has an operating voltage of DC12 to 24V, a screen structure of 5 digits and a high brightness digital tube.3. USE SCENARIO: Our programmable off line serial controller is widely applied in industrial automation control, small mechanical devices.4. MADE OF PC MATERIAL: The programmable offline sequence controller is made of PC material, which is strong and durable.5. LIGHT WEIGHT: Our programmable offline sequence controller is light weight and easy to install and very practical and helpful.Specification:Item Type: Programmable controllerMaterial: PCHousing Size: Approx. 99.7 x 72 x 17mm / 3.93 x 2.83 x 0.67in (L x W x H)Screen Structure: 5 digit, high brightness digital tubeOperating Environment: -5- 60 (no condensation) Working Voltage: DC12-24V, >1.5A, power supplyOpening Size: Approx. 92 x 69.8mm / 3.62 x 2.75in (L x W)Output: 5 outputs <0.8A, output voltage 0V Input: 5 programmable inputs, 2 fixed inputsSerial numberFunctionRangeDefault valueF0Cycle working times Unit: times (demonstrated below) 0-65534, 65535 for countless times1F1Number of rows at the beginning of the loop Unit: rows (Demonstrated below)0-400If the number of lines at the beginning of the loop > the number of lines at the end of the loop, it is illegal. Will alarmF2Number of rows at the end of the loop Unit: rows (demonstrated below)0-4040Illegal if the number of lines at the beginning of the loop > the number of lines at the end of the loop. Will alarmF3Open [Output] manual debugging interface (restart to exit automatically or press [Return])Introduced below0F4Open [Input] manual debugging interface (restart to exit automatically or press [Return])Introduced below0F5Turn on programming mode (restart to exit automatically)0-10If you do not turn on the programming privileges, it is not possible to change the programming statements and alarm0: Turn off programming privileges (power off automatically changes to 0) 1: Turn on programming privilegesF15Adjust the amplitude value of [overall working time] during operation Unit:second0-65535.999 , 0=no speed change during operation0F16Auto run at power on specified program line: 31-40 lines0-200 Turn off. If turned off, program segment 31-40 lines will automatically act as normal program category1 Power on automatically runs program segment 31-40 lines. 2 The power on automatically works.F17Action when ESC emergency stop key is pressed0-200 Program ends and turns off all outputs 1 Program ends and holds current state2 Program ends and runs program segment lines 31-40If parameter 2 is not selected, then program lines 31-40 automatically act as normal program categoriesF18Selectively switch P interface or F interface 0-301 Off [P interface] on [F interface] 2 On [P interface] off [F interface]3 All off (temporary open: press [Set] key before power on) 0 All onF19Main interface display content 0-200 Realtime working status. Display the total number of working times (not the number of cycles) under standby 1 Displays the number of cycles (not the total number) 2 Displays what line of program the system is runningF20Port filtering time of input port 0-65535120Set again when there is external interference. The higher the value, the slower the response Unit: LevelF21Start or emergency stop button signal filtering time on the panel 0-6553527Set again when there is external interference. The higher the value, the slower the response Unit: LevelF24Restore the factory setting 0-44Note: After changing this parameter, you need to power off and restart1 Restore [F] parameter only 2 Restore [P] parameter only3 Restore all 4 No need to restore 0 or >10: restore all and open self test mode, factory mode (only for factory use).Package List:1 x Programmable ControllerNote:Prohibited for use in the following industries.1. Iatrical equipment.2. Elevators, fire fight, boiler equipment, power generation equipment, mining equipment and other special industries or life vital areas.
  • Nº de Fruugo : 387482465-831832413
  • EAN: 6950044977216

Información de seguridad del producto

Consulte la información de seguridad del producto específica de este producto que se describe a continuación.

La siguiente información es proporcionada por el minorista independiente que vende este producto.

Etiquetas de seguridad del producto

CE Mark
Advertencias de seguridad: Please read the instructions and precautions before use
Ingredientes: 75% plastic and 25% metal

Entrega y devolución

Enviado en un plazo de 10 días

  • STANDARD: 10,49 € - Entrega entre jue 18 diciembre 2025–jue 25 diciembre 2025

Envío desde China.

Hacemos todo lo posible para asegurarnos de que se le entreguen los productos que pida en su totalidad y de acuerdo con sus especificaciones. Sin embargo, si recibe un pedido incompleto o artículos diferentes a los que pidió, o hay alguna otra razón por la que no está satisfecho con el pedido, puede devolver el mismo o cualquier producto incluido en él y obtener un reembolso completo por los artículos. Vea la política de devolución completa

Detalles de cumplimiento del producto

Consulte la información de cumplimiento específica de este producto que se describe a continuación.

La siguiente información es proporcionada por el minorista independiente que vende este producto.

Fabricante:
La información que se proporciona a continuación incluye los datos de contacto del fabricante del producto de referencia a la venta en Fruugo.

  • Shenzhenshiaichuangyouwangluokejiyouxiangongsi
  • MEIQUAN PAN
  • 517-C, Block 543, Bafengling Industrial Zone
  • Bagua 2nd Road, Hualin Village District, Yangling Street, Futian District
  • Shenzhen 518000 China
  • Shenzhen
  • CN
  • 518000
  • xincheng23@hotmail.com
  • 18679230808

Persona responsable en la UE:
La información que se proporciona a continuación incluye la información de contacto de la persona responsable en la UE. La persona responsable es el agente económico designado con sede en la UE responsable de las obligaciones de cumplimiento en relación al producto de referencia a la venta en la UE.

  • Axitera GmbH
  • Axitera GmbH
  • Kreuznacher Str. 30, D-60486 Frankfurt am Main, Hessen, Germany
  • Frankfurt
  • Germany
  • D-60486
  • infonoticeeran@gmail.com
  • (+49) 6934873848