Digital LCD Flow Meter Indicator for Diesel, Gasoline, Oil, and Methanol Fuels

42,95 €
envío GRATUITO

Digital LCD Flow Meter Indicator for Diesel, Gasoline, Oil, and Methanol Fuels

  • Marca: Unbranded
Vendido por:

Digital LCD Flow Meter Indicator for Diesel, Gasoline, Oil, and Methanol Fuels

  • Marca: Unbranded

42,95 €

Ahorre 16,05 € (27%)

PVP

59,00 €
En existencias
envío GRATUITO
Vendido por:

42,95 €

Ahorre 16,05 € (27%)

PVP

59,00 €
En existencias
envío GRATUITO

Aceptamos los siguientes métodos de pago

Descripción

Item Type: Flow MeterMaterial: ABSStandard: VerticalMedia: Methanol, diesel fuel, kerosene, chemical liquid, urea waterImporters: 1in internal threadMeasurement Accuracy: 1%Repeatability: 0.5%Maximum Working Pressure: 20BAROperating Voltage: 2.3 - 3.3VStandby Time: 2 YearsFlow Range: 10 - 120L / MINSingle Count: 0.00 - 999.9Total Cumulative Number: 0.00 - 999999.9Unit: L / L, gal / GAL, pint / PTS, quart / QTSSingle Measurement Cleared: RESETBattery: Built-in battery, 2 x AAA batteries, 500mAh(include batteries)Setting Units of Measurement:1. In the standby mode, or raise the amount of current display state2. Press CAL + RESET button for 5 seconds3. Enter unit conversion settings, press the RESET button4. Followed by LTR - GAL - PT -QT - LTR choose the unit of measurement5 .While the cumulative filling volume displayed in the current unit of measure conversion after6. Press the MENU key for 3 seconds to exit the unit conversion settings.Operating Instructions1. Measuring Unit SettingUnder standby state or current amount display state, press and hold MENU+RESET buttons for 5 seconds to enter unit conversion setting, then press RESET button to select unit in turn of LTR - GAL - PT - QT - LTR. Press and hold MENU button for 3 seconds to exit unit conversion setting.2. Accumulative and Current Amount ResetPress and hold RESET button and LCD screen displays on full screen, wait till the full screen display end then loose the RESET button. At this time the accumulative amount and current amount is reset.3. Error Coefficient and Accumulative Amount InquireUnder standby state, press MENU + RESET button together, then LCD display shows the error coefficient on the upper row, and accumulative amount on the lower row.4. Error Coefficient CalibrationUnder standby state or current amount display state, press and hold MENU button for 3 seconds to enter error coefficient calibration mode. The first digit flashes, press MENU button to change position of the digit, and press RESET button to change digit. As this coefficient increases, output oil quantity reduces. Then press and hold MENU button for 3 seconds to end error coefficient calibration and return to current amount display state, and the current amount is reset as zero. The calibration error coefficient range is 0.1000 to 9.9999. For example, original coefficient is 1.000, when it displays 100 liters output of oil, the actual oil output is 100L. If you need 2 liter reduced, set the coefficient as 1.020, then the output would be 98L.5. MaintenanceWhen battery voltage is too low, a battery symbol appears on the LCD display, which reminds user to replace battery. Too short battery life can cause damage to the meter because of battery leakage. This meter has designed standby life of about two years, but we suggest customer to replace a battery each year, and check battery electrodes if there is any rust. Battery should be removed if not usi1The flowmeter control panel adopts modular design, multiple measurement units conversion, complete functions, convenient operation and simple structure.2It can be used to measure methanol, kerosene, diesel, fuel, urea water. It is widely used in petroleum, chemical, pharmaceutical, transportation, food and other industries and commercial fields.3Digital LCD display, high?definition display shows instantaneous and cumulative flow and NPT counter.4Clear and accurate measurement, intuitive and clear reading, high reliability, measurement accuracy 1%.54 unit options, liter (L) / gallon (GAL) / pint (PTS) / quart (QTS), used in different countries. Easy to clean, install and maintain.1. This product requires 2 x AAA batteries, more convenient for you to use, and comes with 2 x AAA batteries replaceable batteries2. Hint of insufficient battery power: LBAT is displayed when the battery voltage is 2.2V ? 2.4V to remind the user to replace the battery.3. Please note that the new type and old type of this product will be sent randomly, and make sure you will not mind before ordering.1 xFlowMeter1 x Adapter2 x Rubber Seal Ring
  • Nº de Fruugo : 421660262-888053296
  • EAN: 6473758201137

Información de seguridad del producto

Consulte la información de seguridad del producto específica de este producto que se describe a continuación.

La siguiente información es proporcionada por el minorista independiente que vende este producto.

Etiquetas de seguridad del producto

CE Mark
Advertencias de seguridad: WARNING: TO AVOID DANGER OF SUFFOCATION, KEEP THIS PLASTIC BAG AWAY FROM BABIES AND CHILDREN.

Entrega y devolución

Enviado en 24 horas

  • STANDARD: GRATIS - Entrega entre vie 05 diciembre 2025–lun 15 diciembre 2025 - GRATIS

Envío desde China.

Hacemos todo lo posible para asegurarnos de que se le entreguen los productos que pida en su totalidad y de acuerdo con sus especificaciones. Sin embargo, si recibe un pedido incompleto o artículos diferentes a los que pidió, o hay alguna otra razón por la que no está satisfecho con el pedido, puede devolver el mismo o cualquier producto incluido en él y obtener un reembolso completo por los artículos. Vea la política de devolución completa

Detalles de cumplimiento del producto

Consulte la información de cumplimiento específica de este producto que se describe a continuación.

La siguiente información es proporcionada por el minorista independiente que vende este producto.

Fabricante:
La información que se proporciona a continuación incluye los datos de contacto del fabricante del producto de referencia a la venta en Fruugo.

  • CREA
  • CREA
  • 1-3 Boulevard Charles de Gaulle Colombes 92700 FR
  • Colombes
  • FR
  • 92700
  • xmchymx@outlook.com
  • 86-13312976782
  • https://www.fruugo.co.uk/huizhou-yuhengda-trading/m-14512

Persona responsable en la UE:
La información que se proporciona a continuación incluye la información de contacto de la persona responsable en la UE. La persona responsable es el agente económico designado con sede en la UE responsable de las obligaciones de cumplimiento en relación al producto de referencia a la venta en la UE.

  • E-CrossStu GmbH
  • E-CrossStu GmbH
  • Mainzer Landstr.69,60329 Frankfurt am Main,Hessen, Deutschland
  • Frankfurt am Main
  • DE
  • 60329
  • E-CrossStu@web.de
  • +4969330000000
  • https://www.fruugo.co.uk/huizhou-yuhengda-trading/m-14512