DC Current Detection Module, 10A Relay Output, YYI-2 Model, Digital Display Motor Controller 12V

21,95 €
+ 8,49 € Envío

DC Current Detection Module, 10A Relay Output, YYI-2 Model, Digital Display Motor Controller 12V

  • Marca: Unbranded
Vendido por:

DC Current Detection Module, 10A Relay Output, YYI-2 Model, Digital Display Motor Controller 12V

  • Marca: Unbranded

21,95 €

Ahorre 12,00 € (35%)

PVP

33,95 €
En existencias
+ 8,49 € Envío

Política de devoluciones de 14 días

Vendido por:

21,95 €

Ahorre 12,00 € (35%)

PVP

33,95 €
En existencias
+ 8,49 € Envío

Política de devoluciones de 14 días

Métodos de pago:

Descripción

DC Current Detection Module, 10A Relay Output, YYI-2 Model, Digital Display Motor Controller 12V

①. DC Current Detection Module Relay Switch Sensor Digital Display Motor Controller 12V ②. Item Type: DC Current Detection Module ③. Product Model: YYI-2. When the detection current is too large or too small, the control relay switch will control the circuit to be on or off, or give a signal; ④. Detection Accuracy: 0.01A (10mA) ⑤. Error Calibration: With error calibration function, and the display can be turned off for a long time to reduce power consumption; ⑥. Standby Current: About 20mA; ⑦. Relay Output: Can control the on and off of DC lines within 10A; ⑧. Function ⑨. 1. P-11: When the measured current is greater than I1, the relay is closed; when the measured current is less than I1 again, the relay is disconnected; ⑩. 2. P-12: When the measured current is greater than I1, the relay is closed; and it will always stay closed until the circuit board is powered off; ⑪. 3. P-21: When the measured current is greater than I2, the relay is closed; when the measured current is less than I1, the relay is disconnected; ⑫. 4. P-22: When the measured current is greater than I2, the relay is closed; and it will always stay closed until the circuit board is powered off; ⑬. 5. P-31: When the measured current is less than I1, the relay is closed; when the current is greater than I2, the relay is disconnected; ⑭. 6. P-32: When the measured current is less than I1, the relay is closed; and it will always stay closed until the circuit board is powered off; ⑮. 7. P-41: When the measured current is between I1 and I2, the relay is closed, otherwise the relay is disconnected; ⑯. 8. P-42: When the measured current is between I1 and I2, the relay is closed; and it will always stay closed until the circuit board is powered off; ⑰. 9. P-51: When the measured current is less than I1 or greater than I2, the relay is closed, otherwise the relay is disconnected; ⑱. 10. P-52: When the measured current is less than I1 or greater than I2, the relay is closed; and it will always stay closed until the circuit board is powered off; ⑲. Setting Instructions: ⑳. 1. Power on to display the measured current; (if the measured current terminal is suspended, the number of digital display is normal); ㉑. 2. The first time K1 is pressed, it takes more than 1 second to be effective to prevent false triggering. The screen displays: P 11: K2 adjustment mode, K3 adjustment function; ㉒. 3. Press K1 for the second time, the screen flashes: 0.05 means that the value of the threshold I1 is 0.05A; K2 sets I1 plus, K3 sets I1 minus; ㉓. 4. Press K1 for the third time, the screen flashes: 0.10 means the value of the threshold I2 is 0.1A; K2 sets I2 plus, K3 sets I2 minus; ㉔. 5. Press K1 for the fourth time, the screen displays the measured current; it means it enters the standby state; ㉕. 6. In standby mode, long press K2 or K3 to fine tune the measured current error.
  • Nº de Fruugo : 462328378-973119946

Entrega y devolución

Enviado en un plazo de 3 días

  • STANDARD: 8,49 € - Entrega entre lun 09 febrero 2026–mié 18 febrero 2026

Envío desde China.

Hacemos todo lo posible para asegurarnos de que se le entreguen los productos que pida en su totalidad y de acuerdo con sus especificaciones. Sin embargo, si recibe un pedido incompleto o artículos diferentes a los que pidió, o hay alguna otra razón por la que no está satisfecho con el pedido, puede devolver el mismo o cualquier producto incluido en él y obtener un reembolso completo por los artículos. Vea la política de devolución completa

Detalles de cumplimiento del producto

Consulte la información de cumplimiento específica de este producto que se describe a continuación.

La siguiente información es proporcionada por el minorista independiente que vende este producto.

Fabricante:
La información que se proporciona a continuación incluye los datos de contacto del fabricante del producto de referencia a la venta en Fruugo.

  • Guangzhou Qiyi E-Commerce Co., Ltd.
  • LnitOne2
  • 3 Tangdong East Road, Unit 216, G282
  • Tianhe District
  • Guangzhou
  • china
  • 510620
  • qiyihappiness@163.com
  • (+86) 16620020838

Persona responsable en la UE:
La información que se proporciona a continuación incluye la información de contacto de la persona responsable en la UE. La persona responsable es el agente económico designado con sede en la UE responsable de las obligaciones de cumplimiento en relación al producto de referencia a la venta en la UE.

  • Jessie Peng
  • Axitera GmbH
  • Kreuznacher Str. 30, D-60486 Frankfurt am Main, Hessen,
  • Frankfurt am Main
  • Germany
  • 60486
  • successservice3@gmail.com
  • (+49) 6934873848